mtlcl410andClaude Opus 5.5 3275f853c3 M2: an Indexed image whose lookup table is short or whose hival is out of range is drawn as other readers draw it, with a warning (ISO 32000-2 8.6.6.3)
Patch (60) skipped such an image. A reviewer's side-by-side tests on #4393
(seven cases against main and Chrome's viewer) showed the skip dropped
colours other readers draw, and regressed a real hival that main draws.
Indexed::new now recovers instead:
- a lookup table shorter than m x (hival + 1) bytes, missing, or not a
  string or decodable stream is padded with zero bytes;
- a hival past 255 is taken as 255;
- a real hival is truncated toward zero (as upstream read it).
The space records that it was recovered. ImageXObject::new raises
MalformedIndexedImage from the space it built; a cs/CS colour in such a
space reports ColorFallback, as the upstream DeviceGray fallback did. A
hival below zero or not a number has no reading: the space falls back as
upstream, and the image reports the warning. Index values past hival
stay clamped (8.6.6.3).

The separate is_malformed_indexed check is gone, so no lookup table is
read twice: inline images naming an Indexed resource read its table once
through the resource cache (CodeRabbit, interpret/mod.rs:945). The read
count is exposed as InterpreterCache::indexed_lookup_reads.

Tests: indexed_lookup.rs rewritten as draw tests (17, cases A-G and
bounds); raster::tests::indexed_lookup_cache. On b6f93a3ae logic 14 of
the 17 fail (the three that pass are guards: full table, case C, device
name) and the cache test reads [21, 41] instead of [1, 1].

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Pq7HyCfwzyRXj4VfQAVVdv