Commit Graph
2 Commits
Author SHA1 Message Date
Guillem Hermida 282ce56675 M12: the page side of a measuring scale takes a unit, so 1:50 is 1 mm = 50 mm (#2752)
The Measure panel's drawing scale had its page side fixed in PDF points, so
"1 = 50 mm" was stored as 1 pt = 50 mm and every length came out
72 / 25.4 = 2.835 times too big (a 1:50 plan needed 50 x 25.4 / 72 = 17.64).

The page side now carries a unit (pt, in, mm, cm). It defaults to the
real-world unit, and to the display unit when that is not one of the four.
Scale::ratio converts it to points before building the /X, /D and /A number
formats (ISO 32000-2 12.9) and writes /R as entered ("1 mm = 50 mm").
measure_scale takes the same ratio through page_distance and page_unit.
Scales read from files, Scale::calibrate and units_per_point are unchanged.

Fixes #2752
2026-10-16 17:25:26 +02:00
6974c6550d Measure: add distance, perimeter and area tools (#208)
* M12: add calibrated 2D measurement tools

* M12: harden measurement tools for landing (#208)

Bounded snap targets (endpoints only for accepted segments, page-wide cap),
lenient extraction (deep q nesting and undecodable streams are skipped and
reported), per-page snap cache, measure::list reports unsupported entries
instead of failing, closed polygons with a repeated vertex, printable unit
labels (m²), cached panel listing, WinAnsi captions, indirect /VP kept,
measure.export skipped in the command test like other pickers, missing
translations, honest parity (scale and distance partial) and ROADMAP.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

---------

Co-authored-by: Brandon Thomas <echelon@gmail.com>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-08 00:38:57 -04:00